Chapter 5 Reset
If the configuration is incorrect or if your device cannot be accessed, you can reset the
device to the ex works standard settings using the Reset button on the bottom of the
device.
Practically al existing configuration data will then be ignored, only the current user pass-
words are retained. Configurations stored in the device are not deleted and can, if required,
be reloaded when the device is rebooted.
For bintec W1002n proceed as follows:
(1) Switch off your device.
(2) Press the Reset button on your device.
(3) Keep the Reset button on your device pressed down and switch the device back on.
(4) Look at the LEDs:
- Initially all LEDs illuminate.
- The device runs through the boot sequence.
- After the LED has flashed three times, release the Reset button.
- The "" LED flashes and the 0"1  and 0"1  LEDs illuminate if these exist
for the ports that are connected to the Ethernet.
On devices of the WI series, the red 2 LED flashes first. Hold in the Cfg button un-
til the red LED goes out and the green "" LED starts to flash.
Proceed as follows if you also want to reset all the user passwords to the ex works state
and delete stored configurations when resetting the device:
(1) Set up a serial connection to your device. Reboot your device and monitor the boot
sequence. Start the BOOTmonitor (as described in BOOTmonitor on page 72) and
choose the (4) Delete configuration and follow the instructions.
or
(2) Set up a serial connection to your device. First carry out the reset procedure de-
scribed and enter   #"$ as Login at the login prompt in the command
line. Leave the password empty and press the Return key. The device runs through
the boot sequence again.
You can now configure your device again as described from Basic configuration on page
14.